PAM90 Analogue Addressable Fire Alarm Control System
ZAM90 Micro-Computer Controlled Fire Alarm Annunciation System
CAM90 Coventional Fire Alarm System
CO2 Panel Fire Alarm Control System
:: Flight Information
   Display Systems
:: Information Kiosk
   Systems
:: Intelligent Transport
   Systems
:: Lighting Systems
:: Real Time Stock, Foreign
   Exchange and Financial
   Information Display
   Systems
:: Scoreboards and Scoring
   Systems

Fire Alarm Systems

CO2 Panel Fire Alarm System

The CO2 Panel Fire Alarm Control System is a multi-zone fully transistorised automatic fire detection system. It is housed in a signal red coloured mild steel panel.

The alarm indication is both audible (bell ringing) and visible (alarm indicator light flashing). Fault and other indications are also both audible (buzzer sounds) and visible (indicator light on).

The CO2 control circuit used is a double lock system, i.e with two zones on alarm condition and after a time delay of 30 seconds, only then will the CO2 gas be discharged.

 
Fire Alarm Panel
 
CO2 Panel
     
Products Features
Compact design
Mains fail, charger fail and battery fail supervision
Detectors and bell line fault supervision
Regulated DC Power Supply
Two-wire Smoke and Heat Detector Compatible
24 V DC Operation

System Specifications

AC INPUT VOLTAGE 230V +/-10% 50Hz Single Phase
STANDBY BATTERY 24V DC Rechargeable Type
CHARGER OUTPUT VOLTAGE 28V DC (with short circuit protection)
SYSTEM VOLTAGE 25V DC (with short circuit protection)
END-OF-LINE RESISTOR 22KOhm
OUTPUT TO BELL 24V DC
TRIPPING OUTPUT 24V DC
CURTAIN TRIP Zone 1 & Zone 2 alarm, 24V DC will be sent to trip the curtain
BELL INTERMITTENT Zone 1 alarm, bell intermittent ringing
Zone 2 alarm, bell intermittent ringing
Zone 1 & 2 alarm, bell ringing continuously
NO. OF SENSORS PER ZONE Indefinite. Sensors must be open and provide a short circuit contact on alarm condition
CO2 DISCHARGE OUTPUT 24V DC when actuated
   
 